1.
J Bodyw Mov Ther ; 36: 386-392, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37949589

RESUMO

INTRODUCTION: Hippotherapy is a physical therapy tool that utilizes horseback riding to improve strength, coordination, gait, and balance. These benefits may be linked to similarities in kinematics and muscle activation between horseback riding and normal human gait, but this is not well represented in the literature, especially for muscle activation. The purpose of this study was to investigate the relationships between muscle activation of horseback riding and healthy human gait. METHODS: The muscle activation of nine healthy female participants (age 18-22) were recorded during walking and horseback riding trials using surface electromyography (EMG). Muscles analyzed include rectus abdominis, lumbar erector spinae, rectus femoris and biceps femoris. Activation waveforms during walking and riding were generated, and from this average and maximum contraction magnitudes were recorded. RESULTS: Average muscle activation was significantly greater in riding for the left (p = 0.008) and right (p = 0.04) biceps femoris. Additionally, average and maximal activation of the left erector spinae were significantly greater in riding (W = 4; critical value for W at n = 9 is 5). Remaining differences in muscle activation between walking and riding were non-significant. DISCUSSION: Peak and average muscle activation magnitude across the gait cycle were similar for most muscle groups. When present, differences were greater in riding. Despite these similarities, EMG waveforms displayed more predictable temporal patterns in walking. CONCLUSION: These findings suggest that hippotherapy could be used to elicit muscle excitation similar to that of normal gait, which may have promising implications for rehabilitation targeting gait correction.


Assuntos
Coxa da Perna , Caminhada , Humanos , Feminino , Adolescente , Adulto Jovem , Adulto , Caminhada/fisiologia , Músculo Esquelético/fisiologia , Marcha/fisiologia , Eletromiografia , Fenômenos Biomecânicos
2.
Med Eng Phys ; 115: 103978, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37120178

RESUMO

Custom foot orthoses are used to treat a variety of foot pathologies. However, orthotic production requires significant hands-on fabrication time and expertise to produce orthoses that are both comfortable and effective. This paper introduces a novel 3D printed orthosis and fabrication method that utilizes custom architectures to produce variable-hardness regions. These novel orthoses are compared to traditionally fabricated orthoses during a 2-week user comfort study. Twenty (n = 20) male volunteers underwent orthotic fitting for both traditional and 3D-printed foot orthoses prior to engaging in treadmill walking trials and 2 weeks of wear. Each participant undertook a regional comfort, acceptance, and comparison analysis of the orthoses at three time points throughout the study (0, 1, and 2 weeks). Both the 3D-printed and the traditionally fabricated foot orthoses demonstrated statistically significant increases in comfort when compared to the factory fabricated shoe insert. Additionally, the two orthosis groups were not significantly different from each other in comfort rankings both regionally and overall at any time point. The similar comfort achieved by the 3D-printed orthosis to the traditionally fabricated orthosis after 7 days and 14 days emphasizes the potential of the future use of the more reproducible and adaptable 3D-printed orthosis manufacturing methodology.


Assuntos
Órtoses do Pé , Humanos , Masculino , Dureza , , Caminhada , Impressão Tridimensional , Desenho de Equipamento
3.
Shoulder Elbow ; 14(6): 606-614, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36479005

RESUMO

Background: In a reverse total shoulder arthroplasty, the altered glenohumeral joint center of rotation subjects the glenoid baseplate to increased shear forces and potential loosening. Methods: This study examined glenoid baseplate micromotion and initial fixation strength with the application of direct shear force in a Sawbone model. The reverse total shoulder arthroplasty systems examined were the DJO Reverse® Shoulder Prosthesis, the Exactech Equinoxe® Reverse System, and the Tornier AequalisTM Reverse Shoulder Prosthesis. Specimens were cyclically tested with increasing shear loads until 150 µm of displacement between the implant and glenoid was achieved, and subsequently until failure, classified as either 1 cm of implant/glenoid displacement or fracture. Results: The average load withstood for the 150 µm threshold for DJO, Tornier, and Exactech was 460 ± 88 N, 525 ± 100 N, and 585 ± 160 N, respectively. The average total load at device failure for DJO, Tornier, and Exactech was 980 ± 260 N, 1260 ± 120 N, and 1350 ± 230 N, respectively. Discussion: The Exactech implant design trended toward requiring more load to induce micromotion at each threshold and to induce device failure, most commonly seen as inferior screw pull out. This study proposes design features that may enhance fixation and suggests little risk of initial micromotion or failure during initial post-operative recovery.

4.
Ann Biomed Eng ; 50(11): 1608-1619, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35867315

RESUMO

The purpose of this study was to compare the effects of wearing older, lower-ranked football helmets (LRank) to wearing newer, higher-ranked football helmets (HRank) on pre- to post-season changes in cortical thickness in response to repetitive head impacts and assess whether changes in cortical thickness are associated with head impact exposure for either helmet type. 105 male high-school athletes (NHRank = 52, NLRank = 53) wore accelerometers affixed behind the left mastoid during all practices and games for one regular season of American football to monitor head impact exposure. Pre- and post-season magnetic resonance imaging (MRI) were completed to assess longitudinal changes in cortical thickness. Significant reductions in cortical thickness (i.e., cortical thinning) were observed pre- to post-season for each group, but these longitudinal alterations were not significantly different between the LRank and HRank groups. Further, significant group-by-head impact exposure interactions were observed when predicting changes in cortical thickness. Specifically, a greater frequency of high magnitude head impacts during the football season resulted in greater cortical thinning for the LRank group, but not for the HRank group. These data provide preliminary in vivo evidence that HRank helmets may provide a buffer between the specific effect of high magnitude head impacts on regional thinning by dissipating forces more evenly throughout the cortex. However, future research with larger sample sizes, increased longitudinal measures and additional helmet technologies is warranted to both expand upon and further validate the present study findings.


Assuntos
Concussão Encefálica , Futebol Americano , Masculino , Humanos , Dispositivos de Proteção da Cabeça , Afinamento Cortical Cerebral , Estações do Ano , Tecnologia
5.
Biomed Eng Educ ; 2(1): 1-16, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-35599985

RESUMO

This paper provides a synopsis of discussions related to the Learning Environments track of the Fourth BME Education Summit held at Case Western Reserve University in Cleveland, Ohio in May 2019. This summit was organized by the Council of Chairs of Bioengineering and Biomedical Engineering, and participants included over 300 faculty members from 100+ accredited undergraduate programs. The Learning Environments track had six interactive workshops that provided facilitated discussion and provide recommendations in the areas of: (1) Authentic project/problem identification in clinical, industrial, and global settings, (2) Experiential problem/project-based learning within courses, (3) Experiential learning in co-curricular learning settings, (4) Team-based learning, (5) Teaching to reach a diverse classroom, and (6) innovative platforms and pedagogy. A summary of the findings, best practices and recommendations from each of the workshops is provided under separate headings below, and a list of resources is provided at the end of this paper.

6.
J Aging Phys Act ; 30(5): 906-915, 2022 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-35130516

RESUMO

The biomechanical relationship between horse and rider in equine-assisted activities and therapies has been largely unexplored. The three-dimensional stimulation of the horse's gait has potential to improve rider musculature and coordination, especially in an older adult population. This study utilized dual-axis goniometers and video motion capture tracking to simultaneously track horse and rider hip flexion and extension. Ten older adult riders participated in 8 weeks of horseback riding lessons, where pelvis kinematics and balance assessments were compared between Weeks 1 and 8. Pelvic roll of the rider and horses' hip flexion and extension were successfully tracked and summed improvements in balance assessments were also evident after 8 weeks of horseback riding lessons. Future research will assess deeper kinematic relationships between a horse's gait and rider biomechanical responses.


Assuntos
Movimento , Esportes , Animais , Fenômenos Biomecânicos/fisiologia , Marcha/fisiologia , Cavalos , Humanos , Movimento/fisiologia , Pelve/fisiologia
7.
J Am Coll Emerg Physicians Open ; 3(1): e12656, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35112100

RESUMO

OBJECTIVES: To overcome the shortage of personal protective equipment and airborne infection isolation rooms (AIIRs) in the COVID-19 pandemic, a collaborative team of research engineers and clinical physicians worked to build a novel negative pressure environment in the hopes of improving healthcare worker and patient safety. The team then sought to test the device's efficacy in generating and maintaining negative pressure. The goal proved prescient as the US Food and Drug Administration (FDA) later recommended that all barrier devices use negative pressure. METHODS: Initially, engineers observed simulations of various aerosol- and droplet-generating procedures using hospital beds and stretchers to determine the optimal working dimensions of the containment device. Several prototypes were made based on these dimensions which were combined with filters and various flow-generating devices. Then, the airflow generated and the pressure differential within the device during simulated patient care were measured, specifically assessing its ability to create a negative pressure environment consistent with standards published by the Centers for Disease Control and Prevention (CDC). RESULTS: The portable fans were unable to generate any airflow and were dropped from further testing. The vacuums tested were all able to generate a negative pressure environment with the magnitude of pressure differential increasing with the vacuum horsepower. Only the 3.5-horsepower Shop-Vac, however, generated a -3.0 pascal (Pa) pressure gradient, exceeding the CDC-recommended minimum of -2.5 Pa for AIIRs. CONCLUSION: A collaborative team of physicians and engineers demonstrated the efficacy of a prototype portable negative pressure environment, surpassing the negative pressure differential recommended by the CDC.

8.
Build Environ ; 207: 108467, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34720358

RESUMO

The emergence of the SARS-CoV-2 pandemic has imposed a multitude of complications on healthcare facilities. Healthcare professionals had to develop creative solutions to deal with resource shortages and isolation spaces when caring for COVID positive patients. Among many other solutions, facilities have utilized engineering strategies to mitigate the spread of viral contamination within the hospital environment. One of the standard solutions has been the use of whole room negative pressurization (WRNP) to turn a general patient room into an infection isolation space. However, this has not always been easy due to many limitations, such as direct access to the outdoors and the availability of WRNP units. In operating rooms where a patient is likely to go through aerosol-generating procedures, other solutions must be considered because most operating rooms use positive pressure ventilation to maintain sterility. The research team has designed, built, and tested a Covering for Operations during Viral Emergency Response (COVER), a low-cost, portable isolation chamber that fits over a patient's torso on a hospital bed to contain and remove the pathogenic agents at the source (i.e., patient's mouth and nose). This study tests the performance of the COVER system under various design and performance scenarios using particle tracing techniques and compares its efficiency with WRNP units. The results show that COVER can dramatically reduce the concentration of particles within the room, while WRNP is only effective in preventing the room-induced particles from migrating to adjacent spaces.

9.
Proc Inst Mech Eng H ; 235(11): 1257-1264, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34289763

RESUMO

This biomechanical study evaluates the performance of a solid titanium-alloy intra-medullary (IM) clavicular screw in torsion and cantilever bending in cadaveric clavicle specimens with simulated simple oblique and butterfly wedge midshaft fractures. Thirty-two fresh-frozen male clavicles were sorted into six experimental groups: Torsion Control, Torsion Simple Oblique Fracture, Torsion Butterfly Wedge Fracture, Bending Control, Bending Simple Oblique Fracture, and Bending Butterfly Wedge Fracture. The experimental groups were controlled for density, length, diameter, and laterality. All other samples were osteotomy-induced and implanted with a single 90 mm × 3 mm clavicle screw. All groups were tested to physiologically relevant cutoff points in torsion or bending. There were no statistically significant differences in the performance of the oblique and butterfly wedge fracture models for any torsion or bend testing measures, including maximum torsional resistance (p = 0.66), torsional stiffness (p = 0.51), maximum bending moment (p = 0.43), or bending stiffness (p = 0.73). Torsional testing of samples in the direction of thread tightening tended to be stronger than samples tested in loosening, with all groups either approaching or achieving statistical significance. There were no significant differences between the simple oblique or the butterfly-wedge fracture groups for any of the tested parameters, suggesting that there is no difference in the gross biomechanical properties of the bone-implant construct when the IM clavicle screw is used in either a simple midshaft fracture pattern or a more complex butterfly wedge fracture pattern.


Assuntos
Fixação Interna de Fraturas , Fraturas Ósseas , Fenômenos Biomecânicos , Placas Ósseas , Parafusos Ósseos , Clavícula/cirurgia , Fraturas Ósseas/cirurgia , Humanos , Masculino
10.
Sensors (Basel) ; 21(10)2021 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-34065299

RESUMO

We describe a method to measure micron to millimeter displacement through tissue using an upconversion spectral ruler. Measuring stiffness (displacement under load) in muscles, bones, ligaments, and tendons is important for studying and monitoring healing of injuries. Optical displacement measurements are useful because they are sensitive and noninvasive. Optical measurements through tissue must use spectral rather than imaging approaches because optical scattering in the tissue blurs the image with a point spread function typically around the depth of the tissue. Additionally, the optical measurement should have low background and minimal intensity dependence. Previously, we demonstrated a spectral encoder using either X-ray luminescence or fluorescence, but the X-ray luminescence required an expensive X-ray source and used ionizing radiation, while the fluorescence sensor suffered from interference from autofluorescence. Here, we used upconversion, which can be provided with a simple fiber-coupled spectrometer with essentially autofluorescence-free signals. The upconversion phosphors provide a low background signal, and the use of closely spaced spectral peaks minimizes spectral distortion from the tissue. The small displacement noise level (precision) through tissue was 2 µm when using a microscope-coupled spectrometer to collect light. We also showed proof of principle for measuring strain on a tendon mimic. The approach provides a simple method to study biomechanics using implantable sensors.


Assuntos
Luminescência , Fluorescência , Radiografia , Raios X
11.
J Biomech Eng ; 143(5)2021 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-33493283

RESUMO

While using a prosthesis, transtibial amputees can experience pain and discomfort brought on by large pressure gradients at the interface between the residual limb and the prosthetic socket. Current prosthetic interface solutions attempt to alleviate these pressure gradients using soft homogenous liners to reduce and distribute pressures. This research investigates an additively manufactured metamaterial inlay with a tailored mechanical response to reduce peak pressure gradients around the limb. The inlay uses a hyperelastic behaving metamaterial (US10244818) comprised of triangular pattern unit cells, 3D printed with walls of various thicknesses controlled by draft angles. The hyperelastic material properties are modeled using a Yeoh third-order model. The third-order coefficients can be adjusted and optimized, which corresponds to a change in the unit cell wall thickness to create an inlay that can meet the unique offloading needs of an amputee. Finite element analysis simulations evaluated the pressure gradient reduction from (1) a standard homogenous silicone liner, (2) a prosthetist's inlay prescription that utilizes three variations of the metamaterial, and (3) a metamaterial solution with optimized Yeoh third-order coefficients. Compared to a traditional homogenous silicone liner for two unique limb loading scenarios, the prosthetist prescribed inlay and the optimized material inlay can achieve equal or greater pressure gradient reduction capabilities. These preliminary results show the potential feasibility of implementing this metamaterial as a method of personalized medicine for transtibial amputees by creating a customizable interface solution to meet the unique performance needs of an individual patient.


Assuntos
Membros Artificiais , Cotos de Amputação
12.
Clin Biomech (Bristol, Avon) ; 81: 105244, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33341522

RESUMO

BACKGROUND: While vibration therapy has shown encouraging results across many fields of medicine in the last decade, its role as originally envisioned for bone health remains uncertain. Especially regarding its efficacy in promoting fracture healing, mixed and incomplete outcomes suggest a need to clarify its potential. In particular, the definitive effect of vibration, when isolated from the confounding mechanical inputs of gait and stabilizing instrumentation, remains largely unknown. METHODS: Four cohorts of C57BL/6 male mice underwent single-leg, open fibula fracture. Vibration was applied at 0.3 g to two groups for 20 min/d. At 3 and 6 weeks, fibulae were harvested for microcomputed tomography and 3-point bending to failure. FINDINGS: In bone volume and tissue volume, the groups at each healing time point were statistically not different. At 3 weeks, however, the ratio of bone-to-tissue volume was lower for the vibrated group than control. Likewise, while bone mineral density did not differ, tissue volume density was lowest with vibration. At 6 weeks, mean differences were nominal. Biomechanically, vibration consistently trended ahead of control in strength and stiffness, but did not achieve statistical significance. INTERPRETATION: At this stage of therapeutic development, vibration therapy in isolation does not demonstrate a clear efficacy for bone healing, although further treatment permutations and translational uses remain open for investigation.


Assuntos
Fraturas Ósseas/fisiopatologia , Fraturas Ósseas/terapia , Vibração/uso terapêutico , Animais , Fenômenos Biomecânicos , Densidade Óssea , Modelos Animais de Doenças , Consolidação da Fratura , Fraturas Ósseas/diagnóstico por imagem , Fraturas Ósseas/patologia , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Suporte de Carga , Microtomografia por Raio-X
13.
Wounds ; 32(12): 353-363, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33370244

RESUMO

INTRODUCTION: Compression is integral to the management of edema and the prevention of venous leg ulcers (VLUs). OBJECTIVE: The aim of this study is to assess the sub-bandage pressure distribution under 3 compression applications as well as to assess the impact of an innovative primary wound dressing, applied under the compression products, on pressure distribution. MATERIALS AND METHODS: A series of controlled tests were performed using a simulated leg model (SLM). A pressure mapping sensor and system software was used to measure the interface pressure (IP) and pressure distribution created by the application of 3 different compression systems with and without the addition of an elastic longitudinal stockinette (fuzzy wale compression; FWC). These included: (1) 2-layer cohesive wrap; (2) 3-layer compression application; and (3) 4-layer compression application. The IP was pressure between the SLM and the innovative dressing over which the compression applications were applied. Seven different configurations were tested, including the compression applications alone and in combination with the FWC. In addition to the IP measurements, pressure mapping visualizations were captured with the pressure mapping sensor and system software. A custom MATLAB program was written for data analysis, differentiations in discrete high- and low-pressure locations across the compressed area, and graphing of the pressure readings. RESULTS: The overall average pressure for each testing setup without FWC ranged from 34.65 ± 4.84 mm Hg for the 2L configuration to 63.92 ± 7.08 mm Hg for the 4L configuration. The addition of the FWC resulted in a 19% increase for the 2L, 9% increase for the 3L, and 7% increase for the 4L compression systems. Additionally, it was noted that the inclusion of FWC resulted in a significant change in pressures vertically oriented under the 2-, 3-, and 4-layer compression applications of 34.52 ± 9.06 mm Hg, 99.21 ± 29.81 mm Hg, and 128.96 ± 22.97 mm Hg, respectively. The pressure distribution under the compression alone was observed to be largely uniform except for areas of overlap that produce horizontal bands of elevated pressures. The presence of the primary wound dressing did not have a significant impact on the IP measurements. The addition of FWC to all compression applications demonstrated a vertical distribution of compression along the sensor with alternating areas of little or no compression. CONCLUSIONS: The unique alternating pressure distribution observed in the in vitro pressure testing with the use of FWC in a clinical setting has been observed to produce better edema management and wound edge migration that mirrors the vertical pressure distribution observed in the study. Additional in vitro and in vivo research to evaluate the biophysical impact of IP created by the use of a combination of primary wound dressings and compression applications with focus on the total pressure and the distribution across the surface of intact tissue and open wound bed is warranted.


Assuntos
Bandagens , Úlcera Varicosa , Bandagens Compressivas , Humanos , Pressão , Úlcera Varicosa/terapia
14.
ACS Sens ; 5(3): 711-718, 2020 03 27.
Artigo em Inglês | MEDLINE | ID: mdl-32096404

RESUMO

A luminescent spectral ruler was developed to measure micrometer to millimeter displacements through tissue. The spectral ruler has two components: a luminescent encoder patterned with alternating stripes of two spectrally distinct luminescent materials and an analyzer mask with periodic transparent windows the same width as the encoder stripes. The analyzer mask is placed over the encoder and held so that only one type of luminescent stripe is visible through the window; sliding the analyzer over the encoder modulates the luminescence spectrum acquired through the analyzer windows, enabling detection of small displacements without imaging. We prepared two types of spectral rulers, one with a fluorescent encoder and a second with an X-ray excited optical luminescent (XEOL) encoder. The fluorescent ruler used two types of quantum dots to form stripes that were excited with 633 nm light and emitted at 645 and 680 nm, respectively. Each ruler type was covered with chicken breast tissue to simulate implantation. The XEOL ruler generated a strong signal with negligible tissue autofluorescence but used ionizing radiation, while the fluorescence ruler used non-ionizing red light excitation but required spectral fitting to account for tissue autofluorescence. The precision for both types of luminescent spectral rulers (with 1 mm wide analyzer windows, and measured through 6 mm of tissue) was <2 µm, mostly limited by shot noise. The approach enabled high micrometer to millimeter displacement measurements through tissue and has applications in biomechanical and mechanochemical measurements (e.g., tracking postsurgical bone healing and implant-associated infection).


Assuntos
Medições Luminescentes , Animais , Galinhas , Feminino , Fraturas Ósseas , Luminescência , Glândulas Mamárias Animais , Pontos Quânticos , Tíbia/lesões
15.
J Biomech Eng ; 141(12)2019 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-31596921

RESUMO

The field of engineering is increasingly appreciating the value of diversity for innovative design solutions. Successful engineering depends on our ability to explore constrained parameter spaces for finding the best solutions, and more diverse minds and experiences enable us to explore the entire potential solution space more thoroughly, more quickly, and more creatively. With a goal to expand the diversity of experiences and mindsets in our undergraduate bioengineering curricula, Arusha Technical College (ATC) in Arusha, Tanzania and Clemson University (CU) in Clemson, South Carolina, U.S., have partnered together over the past 5 years to provide intercontinental educational opportunities for undergraduate students, graduate assistants, and faculty. In 2018, CU and ATC collaborated on an international design course targeting undergraduate students in biomedical engineering focused on global health solutions for resource poor communities. Undergraduate students from ATC and CU collaborated on design projects through formal videoconferenced group meetings, e-mail, and various social media platforms. The year ended with a joint design symposium in Arusha where the students presented on their work in a public poster forum. This successful ATC-CU Global Health Design Collaboration pilot year provides a solid model upon which to build. Students reported overall positive experiences and plans to continue in their curriculum to graduation, as well as some ATC and CU students changing their career direction to include global health initiatives.

16.
J Equine Vet Sci ; 77: 125-131, 2019 06.
Artigo em Inglês | MEDLINE | ID: mdl-31133306

RESUMO

Although horseback riding is a well-established means of rehabilitation therapy for a variety of human patients, there are few data on the biomechanical relationships between horse and rider during such hippotherapy. We simultaneously tracked the movements of a horse with several different novice riders, under conditions similar to hippotherapy, to evaluate whether horses pass the same motion to different riders while being lead at a walk. Riders were outfitted with a goniometric data collection system that recorded the angles of flexion and extension and lateral bending of the thoracic and lumbar spine, as well as the flexion, extension, abduction, and adduction of each hip. We found consistent rhythmic motion in the horse's hock, shoulder, and knee. There were no significant differences in equine movement across six different riders, supporting the conclusion that horses can be used as a reproducible rehabilitation platform for riders. Moreover, although riders demonstrated different baseline postures, there were no significant differences in their ranges of motion in each joint. These results indicate that a horse can reproducibly influence a population of participants in a hippotherapy situation.


Assuntos
Terapia Assistida por Cavalos , Animais , Fenômenos Biomecânicos , Cavalos , Humanos , Movimento , Coluna Vertebral , Caminhada
17.
Proc Inst Mech Eng H ; 233(7): 723-734, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31090486

RESUMO

Knee arthrodesis is commonly performed to treat joint pain and instability in cases of multiple failed knee replacement surgeries, bone loss, traumatic injury, infection, or loss of the quadriceps extensor mechanism, but its mechanics are poorly understood. This study quantified the changes in gait kinematics and kinetics induced by simulating knee arthrodesis. A total of 10 healthy subjects (M/F, n = 5/5; aged 18-23) with no history of gait abnormalities were recruited for this study, and knee arthrodesis was simulated for 0 through 24 h using an immobilizing knee brace. Gait analysis was conducted during level walking on a 15-m walkway using an eight-camera motion tracking system with a six-axis ground reaction force platform. Normal gait served as each subject's control, and measurements of braced gait were taken immediately following the fitting of the brace and over a 24-h acclimation period. Results showed that simulated knee arthrodesis caused statistically significant and interrelated changes to gait when compared to normal gait, including reduced ankle plantar flexion and pelvic obliquity during swing phase of the braced limb, increased abduction of the left and braced hip during stance of the braced limb, and an increase in the net joint reaction force at the contralateral hip. These changes facilitated ground clearance of the braced limb, but however did not show increases in knee flexion moment that might serve as a cyclic fatiguing factor in implants or fusions used to fixate the knee. Increased acclimation time was not found to significantly alter braced gait kinematics, supporting the use of short-term bracing as an experimental model for the longer-term immobilized knee.


Assuntos
Artrodese/instrumentação , Marcha , Joelho/fisiologia , Fenômenos Mecânicos , Aclimatação , Adolescente , Fenômenos Biomecânicos , Braquetes , Feminino , Voluntários Saudáveis , Humanos , Cinética , Masculino , Fatores de Tempo , Adulto Jovem
18.
Analyst ; 144(9): 2984-2993, 2019 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-30888348

RESUMO

A biomedical sensor was developed to measure local pH near orthopedic implants to detect and study implant-associated infection. The sensor is read using plain radiography, a technique which is noninvasive, inexpensive, ubiquitously available in medical facilities, and routinely used in diagnosis and follow-up. The sensor comprises a radiopaque tungsten indicator pin embedded within a chemically responsive hydrogel that exhibits a pH-dependent swelling. A stainless steel well holds this hydrogel and attaches to an orthopedic plate. The local pH may be determined from the extent of hydrogel swelling by radiographically measuring the indicator position relative to the well. We calibrated the sensor in a series of standard pH buffers and tested it during bacterial growth in culture. The sensor was robust: its response was negligibly affected by changes in temperature, ionic strength within the normal physiological range, or long-term incubation with reactive oxygen species generated from hydrogen peroxide and copper. Pooled data from several sensors fabricated at different times and tested in different conditions had a root-mean-square deviation from a pH electrode reading of 0.24 pH units. Radiographic measurements were also performed in cadaveric tissue with the sensor attached to an orthopedic plate fixed to a tibia. Pin position readings varied by 100 µm between observers surveying the same radiographs, corresponding to 0.065 pH units precision in the range pH 4-8. The sensor was designed to augment standard radiographs of tissue, bony anatomy, and hardware by also indicating local chemical concentrations.


Assuntos
Resinas Acrílicas/química , Hidrogéis/química , Próteses e Implantes/microbiologia , Radiografia/métodos , Humanos , Concentração de Íons de Hidrogênio , Staphylococcus aureus/metabolismo
19.
Proc Inst Mech Eng H ; 232(3): 282-288, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29350088

RESUMO

Current total knee replacement designs work to address clinically desired knee stability and range of motion through a balance of retained anatomy and added implant geometry. However, simplified implant geometries such as bearing surfaces, posts, and cams are often used to replace complex ligamentous constraints that are sacrificed during most total knee replacement procedures. This article evaluates a novel total knee replacement design that incorporates synthetic ligaments to enhance the stability of the total knee replacement system. It was hypothesized that by incorporating artificial cruciate ligaments into a total knee replacement design at specific locations and lengths, the stability of the total knee replacement could be significantly altered while maintaining active ranges of motion. The ligament attachment mechanisms used in the design were evaluated using a tensile test, and determined to have a safety factor of three with respect to expected ligamentous loading in vivo. Following initial computational modeling of possible ligament orientations, a physical prototype was constructed to verify the function of the design by performing anterior/posterior drawer tests under physiologic load. Synthetic ligament configurations were found to increase total knee replacement stability up to 94% compared to the no-ligament case, while maintaining total knee replacement flexion range of motion between 0° and 120°, indicating that a total knee replacement that incorporates synthetic ligaments with calibrated location and lengths should be able to significantly enhance and control the kinematic performance of a total knee replacement system.


Assuntos
Artroplastia do Joelho , Ligamentos Articulares , Desenho de Prótese , Teste de Materiais , Fenômenos Mecânicos , Amplitude de Movimento Articular
20.
Proc Inst Mech Eng H ; 231(11): 1034-1047, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-28820012

RESUMO

In total knee replacement surgery, implant alignment is one of the most important criteria for successful long-term clinical outcome. During total knee replacement implantation, femoral and tibial alignment are determined through appropriate bone resections, which could vary based on patient anatomy, implant design and surgical technique and further influence loading conditions and clinical outcomes. The current research focused on three critical alignment parameters for total knee replacement insertion: femoral component internal/external (I/E) rotation, varus-valgus tibiofemoral angulation and posterior tibial slope. A computational finite element model of total knee replacement implant was developed and validated comparing with kinematic outputs generated from experimentally simulated knee joint motion. The FE model was then used to assess 12 different alignment scenarios based on previous case reports. Postoperative knee kinematics and joint contact pressure during simulated gait motion were assessed. According to the parametric study, FE model cases with femoral rotation revealed extra tibial I/E rotation in the predefined direction but negligible change in tibial anterior-posterior translation; cases with increased tibial slope showed notably increased tibial external rotation and anterior translation; cases with varus tibiofemoral angle presented slightly more tibial external rotation, whereas cases with valgus angle presented an observable increase in tibial internal rotation at the middle phase of the gait cycle. Finally, the response surface obtained from the postprocessing study demonstrated good statistical correlation with existing case study results, providing reliable estimation of peak tibiofemoral contact pressure affected by combinations of alignment parameters. The observations indicate that femoral external alignment should be favored clinically for enhanced patellar tracking and reduced contact pressure concentration for better long-term performance. Posterior tibial slope enables deep knee flexion. Extra femoral internal rotation as well as tibiofemoral varus-valgus alignment could be avoided in surgery due to deficiency in patellar tracking and high pressure concentration.


Assuntos
Artroplastia do Joelho , Fêmur , Prótese Articular , Fenômenos Mecânicos , Pressão , Rotação , Tíbia , Fenômenos Biomecânicos , Análise de Elementos Finitos , Humanos